CLICK on Banner for Full Window - MightyBx IVB Parallel Port Signal Pin Assignments
MightyBx IVB Parallel Port Signal Pin Assignments
MightyBx IVB Parallel Port Signal Pin Assignments
Parallel Port connector Pin assignments

The MightyBx IVB uses a standard PC Parallel Port interface to attach to the Desktop computer.  Parallel port signal wires are electronically buffered from the motor driver chips.  Motor step signals are normally low.

Axis X motor Step is on Pin 2, Direction is on Pin 3, Limit Switch on Pin 11.

Axis Y motor Step is on Pin 4, Direction is on Pin 5, Limit Switch on Pin 12.

Relay A is on Pin 4, Relay B is on Pin 5.

Axis Z motor Step is on Pin 8, Direction is on Pin 9, Limit Switch on Pin 13.

HomeMd on Pin 1 must be high during the homing sequence to synchronize the two(2) Y axis motors.

ENABLE on Pin 14 engages the motors when high.

*INIT on Pin 16 disables the controller when Low.

HIPWR on Pin 17 enables high current to motors, when low the current is about 1/3 of the high current.

During machine inactivity the motors are idling at the low power current level to reduce motor heating and provide a holding torque for the attached mechanisms.

MightyBx IVB CNC Controllers for Desktop PCs, Parallel Port or USB interfaces, Stepper or Servomotor XYZ positioning controllersAdjustments Parallel Port Motor Connector Price List SuperCam How to OrderSuper Tech & Associates Home Page


Home Page at http://www.super-tech.com

http://www.super-tech.com/root/grp.asp?p1=EMC-XYYZB-Parallel
Copyright 2013 Dennis Bohlke
Revised 6/09/13
Log On to website as registered user
Legalize Marijuana Constitutional Amendment for the State of Arizona