EMC-XYYZ-BX CNC Machine Tool Controller
Software Program :SuperCam Latest Release Include
Computer Interface :Standard Parallel Port, Female DB25 connector on box
Input Power :28 Volts DC, 35 Ampere
Axis :X, Y1, Y2, Z, the two(2) Y axis motors are Synchronized
Motor Type :Stepper
Motor Sizes :NEMA 23 or NEMA 34 frame size
Motor Drive Configuration :Unipolar Chop Current Limited
Motor Connectors :Female DB9 connector one for each motor
Steps Per Revolution :400 by manufacturing (half step mode) default
Cut and Jumper on Board option to 200 (full step mode)
Minimum Step Pulse Width :5 microsecond, Normally Low
Phase Current :Trimpot Adjustable for each motorMaximum 5 Ampere per phase per Motor
Chop Clock Frequency :55 Khz, trimpot adjustable
Limit Switches :One per Motor Connector, Pin 8 & 9
Y limit switches are used to synchronize Y motors
Relays :Two internal 3 ampere Solid State Relays
Four(4) circuit Terminal block on connector panel for hookup
Switches AC Voltages only, 24 to 145 VAC
Cooling :24 Volt Fan
Cabinet Contruction :All Metal UL approved electrical enclosure
Connections Face Plate :Latching Emergency STOP Switch
Parallel Interface DB25 Female Connector
Four(4) DB9 Female Connectors
Terminal Block, four(4) circuit
Box Size :12" X 12" X 6"
Color :Tool Grey with Black Connection Panel
Mounting Hole Pattern :Four(4) 0.25 holes, 10.0 Inch Square Pattern
Total Shipping Weight :18 lbs
SuperCam Hardware System Requirements
Recent changes to the movement algorithm has made SuperCam more sensitive to the host computer system. It does not work with USB periferals. The keyboard and mouse must be of the PS2 type.
Host Operating System:MS-DOS or Windows 98 or ME
Does Not work with Windows 2000 or XP
Processor :Pentium MMX type or Better
Currently Pentium III 400 Mhz is the development system
Processor Clock Frequency :100 Mhz or Better
Math Co-Processor :Required
Minimum System RAM:8 megabytes
Display Adapter :640 X 480 pixels, 16 colors
System Pointer :PS2 Mouse
Floppy Drive:3.5 inch, 1.44 megabyte
Hard Drive:Required
Parallel Ports :Standard Parallel Port (SPP)
ECP Parallel Ports Do Not Work
Serial Ports :COM1 or COM2
Present with DB9 male connector
XYYZ Unipolar Pictures Specifications Drawings Performance Price List


Home Page at http://www.super-tech.com

http://www.super-tech.com/root/grp.asp?p1=EMC-XYYZ-Specifications
Copyright 2016 Dennis Bohlke
Revised 03/12/16